Free delivery on parcels over R1 500 to main centres* · Pay by card, Instant EFT or pay-later

Blizzard Ice Maker Air Cooled 95kg – SN-210P

R23 412.00

SKU: SD-SDS-ICV-441b1dc0 Categories: , , Brand:

Description

Produces up to 95kg of clear cube ice per day with a 30kg built-in storage bin. Compact and reliable, this air-cooled unit is perfect for cafes, bars, and restaurants. Runs on standard 240V power with premium internal components for long-term performance.

Product Features

  • Up to 95 kg output/24h
  • Bin Storage Capacity: Approx. 28kg
  • U.S. Morrill Water Pump
  • German ËBM-Pabst fans
  • Hisakage PCL
  • 22mm³ ice-cubes
  • Denmark Danfross Expansion Valve & Dry Filter
  • Japanese Saginomiya Solenoid & Hydraulic Valve
  • Unique ice type gives people a feeling of pure and fresh, fashion and cool refreshing
  • Watermark certified product sticker
  • Water filter must be installed otherwise warranty will be void

Product Specifications

  • Product Dimensions (W x D x H mm): 660 x 685 x 920
  • Shipping Dimensions (W x D x H mm): 930 x 900 x 1150
  • Net Weight: N/A
  • Power: 240V, 580W, 10amp plug and lead included

Water Filter Required

This ice maker is not supplied with a water filter, and one must be fitted. It is a condition of the warranty, and it is what gives you clear, hard ice that melts slowly. We recommend the BWT Water Filter for Blizzard Ice Makers – WFI37000, and its cartridge is replaced every 6 months.

6 Monthly Maintenance Program

All ice machines must be maintained to ensure high performance. The cartridge on the water filter system needs to be replaced every 6 months and the unit must be de-scaled to clean the refrigeration evaporator plate. This maintains the quality of the ice shape and thickness.

  • Remove scale and mineral deposits from evaporator plate and water distribution system using approved descaler.
  • Sanitise water reservoir, distribution tubes, and bin interior.
  • Clean and flush condenser coils (air-cooled units).
  • Inspect condenser fan motor and blades.
  • Check inlet water valve, float, and filters for correct operation.
  • Verify ice thickness probe or sensor calibration.
  • Inspect refrigerant pressures, superheat, and subcooling – adjust if necessary.
  • Test compressor amperage and general performance.
  • Inspect water pump operation and clean pump housing.
  • Check harvest cycle operation (heater or hot gas valve).
  • Inspect electrical connections, relays, and contactors.
  • Replace inline water filter cartridge.

This work should be carried out by a qualified refrigeration technician.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.