Free delivery on parcels over R1 500 to main centres* · Pay by card, Instant EFT or pay-later

Blizzard Professional Air-Cooled Ice Maker 450kg – SN-1000P

R57 691.00

Description

The Blizzard SN-1000P is a heavy-duty, professional air-cooled ice maker with a daily output of up to 450kg. Designed for high-volume commercial use, it features premium components, reliable performance, and durable stainless steel construction.

Product Features

  • Output/24h: up to 450kg
  • Storage capacity: approx. 170kg (bin control setting approx. 170kg)
  • U.S. Morrill water pump
  • German ËBM-Pabst fan
  • Italian Aspera compressor
  • Hisakage PCL
  • 22mm³ ice-cube
  • Denmark Danfoss expansion valve & dry filter
  • Japanese Saginomiya solenoid & hydraulic valve
  • Watermark-certified product sticker

Product Specifications

  • Product Dimensions (W x D x H mm): 760 x 830 x 1893
  • Shipping Dimensions (W x D x H mm): 848 x 925 x 1915
  • Net Weight: 126kg
  • Power: 240V, 2.3W, 10amp plug and lead included

* Please note images shown are for indicative purposes only and the actual product or size may vary. Optional Accessories may be shown but not included. Heading and description take precedence over image displayed.

Water Filter Required

This ice maker is not supplied with a water filter, and one must be fitted. It is a condition of the warranty, and it is what gives you clear, hard ice that melts slowly. We recommend the BWT Water Filter for Blizzard Ice Makers – WFI37000, and its cartridge is replaced every 6 months.

6 Monthly Maintenance Program

All ice machines must be maintained to ensure high performance. The cartridge on the water filter system needs to be replaced every 6 months and the unit must be de-scaled to clean the refrigeration evaporator plate. This maintains the quality of the ice shape and thickness.

  • Remove scale and mineral deposits from evaporator plate and water distribution system using approved descaler.
  • Sanitise water reservoir, distribution tubes, and bin interior.
  • Clean and flush condenser coils (air-cooled units).
  • Inspect condenser fan motor and blades.
  • Check inlet water valve, float, and filters for correct operation.
  • Verify ice thickness probe or sensor calibration.
  • Inspect refrigerant pressures, superheat, and subcooling – adjust if necessary.
  • Test compressor amperage and general performance.
  • Inspect water pump operation and clean pump housing.
  • Check harvest cycle operation (heater or hot gas valve).
  • Inspect electrical connections, relays, and contactors.
  • Replace inline water filter cartridge.

This work should be carried out by a qualified refrigeration technician.